{"id":4867,"date":"2025-05-23T05:15:19","date_gmt":"2025-05-23T03:15:19","guid":{"rendered":"https:\/\/med-lab.ibv.org\/implants\/spinal-implant-testing\/"},"modified":"2026-06-23T17:37:35","modified_gmt":"2026-06-23T15:37:35","slug":"spinal-implant-testing","status":"publish","type":"page","link":"https:\/\/med-lab.ibv.org\/en\/implants\/spinal-implant-testing\/","title":{"rendered":"SPINAL IMPLANT TRIALS"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"4867\" class=\"elementor elementor-4867 elementor-2905\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-944200 e-con-full e-flex e-con e-parent\" data-id=\"944200\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-2248436e e-con-full e-flex e-con e-child\" data-id=\"2248436e\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5462c8d2 elementor-widget elementor-widget-heading\" data-id=\"5462c8d2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">\nSPINAL IMPLANT TESTING\n<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-50f6e04 e-grid e-con-full e-con e-parent\" data-id=\"50f6e04\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-12c221ff e-con-full e-flex e-con e-child\" data-id=\"12c221ff\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5de9bb74 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"5de9bb74\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a9a3aaa elementor-widget elementor-widget-text-editor\" data-id=\"a9a3aaa\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-a9a3aaa elementor-widget elementor-widget-text-editor\" data-id=\"a9a3aaa\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-11cc2385 e-con-full e-flex e-con e-child\" data-id=\"11cc2385\" data-element_type=\"container\"><div class=\"elementor-element elementor-element-18c0d1eb elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"18c0d1eb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-a9a3aaa elementor-widget elementor-widget-text-editor\" data-id=\"a9a3aaa\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><p><span style=\"font-weight: 400;\">The<\/span> <b>Instituto de Biomec\u00e1nica (IBV)<\/b> <span style=\"font-weight: 400;\">is a leading center for the evaluation and validation of<\/span> <b>spinal implants<\/b>, <span style=\"font-weight: 400;\">offering specialized tests to analyze their<\/span> <b>structural strength, biomechanical behavior, and mechanical stability<\/b><span style=\"font-weight: 400;\"> across different segments of the spine.<\/span><\/p><p><span style=\"font-weight: 400;\">Spinal implants must withstand<\/span><b> extreme static and dynamic loads <\/b><span style=\"font-weight: 400;\">while ensuring the stability of the operated spinal segment. At IBV, we perform  <\/span><b>customized and complementary tests<\/b><span style=\"font-weight: 400;\"> to validate new design configurations, optimize materials, and improve implant biomechanics prior to certification.<\/span><\/p><p><span style=\"font-weight: 400;\">In addition to delivering test results regarding implant conformity, we provide<\/span><b> technical recommendations<\/b> <span style=\"font-weight: 400;\">to enhance <\/span><span style=\"font-weight: 400;\">functionality and ensure safety within the human body.<\/span><\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4d8fd1e1 e-con-full e-flex e-con e-child\" data-id=\"4d8fd1e1\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-78ba50bb elementor-widget elementor-widget-image\" data-id=\"78ba50bb\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"200\" height=\"300\" src=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/06\/Columna-copia-200x300.png\" class=\"attachment-medium size-medium wp-image-4662\" alt=\"\" srcset=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/06\/Columna-copia-200x300.png 200w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/06\/Columna-copia.png 400w\" sizes=\"(max-width: 200px) 100vw, 200px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<header class=\"elementor-element elementor-element-7cd111c4 e-flex e-con-boxed e-con e-parent\" data-id=\"7cd111c4\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7bdfe26e e-con-full e-flex e-con e-child\" data-id=\"7bdfe26e\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5bad17b5 elementor-widget elementor-widget-shortcode\" data-id=\"5bad17b5\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\"><nav class=\"ibv-breadcrumbs\" aria-label=\"breadcrumbs\"><ul class=\"breadcrumb-list\"><li><a href=\"https:\/\/med-lab.ibv.org\/en\/\">Inicio<\/a><\/li><\/ul><\/nav><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/header>\n\t\t<div class=\"elementor-element elementor-element-26c290a6 e-con-full e-flex e-con e-parent\" data-id=\"26c290a6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-2b210776 e-con-full e-flex e-con e-child\" data-id=\"2b210776\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-78257741 elementor-widget elementor-widget-heading\" data-id=\"78257741\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">INTERVERTEBRAL FUSION SYSTEM TESTING<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3762d34f elementor-widget elementor-widget-text-editor\" data-id=\"3762d34f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-985aac3 elementor-widget elementor-widget-text-editor\" data-id=\"985aac3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-2ec8b47 elementor-widget elementor-widget-text-editor\" data-id=\"2ec8b47\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-66114e00 elementor-widget elementor-widget-text-editor\" data-id=\"66114e00\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-985aac3 elementor-widget elementor-widget-text-editor\" data-id=\"985aac3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><p><strong>Intervertebral fusion systems<\/strong> are designed to provide stability to damaged or degenerated spinal segments, promoting bone consolidation between adjacent vertebrae.<br\/>At IBV, we carry out specific tests to evaluate the strength and durability of these devices under various loading conditions. <\/p><ul><li><strong>Spinal fusion system fatigue testing (ISO 12189)<\/strong>: Evaluation of system resistance under repetitive loading scenarios.<\/li><li><strong>Structural stability and stiffness tests (ASTM F2077)<\/strong>: Analysis of implant behavior under compression and bending loads.<\/li><li><strong>Strength testing of posterior fixation systems<\/strong>: Evaluation of pedicle screws and rods used in lumbar and thoracic fusion surgeries.<\/li><\/ul><p>These tests help optimize the design of intervertebral fusion systems, ensuring their long-term stability and performance.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-14aeee13 e-con-full e-flex e-con e-child\" data-id=\"14aeee13\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-60a2746e elementor-widget elementor-widget-image\" data-id=\"60a2746e\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"770\" height=\"1024\" src=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-21_fijador-raquis-columna-flexo-compresion-OK-1-770x1024.jpg\" class=\"attachment-large size-large wp-image-4697\" alt=\"\" srcset=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-21_fijador-raquis-columna-flexo-compresion-OK-1-770x1024.jpg 770w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-21_fijador-raquis-columna-flexo-compresion-OK-1-226x300.jpg 226w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-21_fijador-raquis-columna-flexo-compresion-OK-1-768x1021.jpg 768w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-21_fijador-raquis-columna-flexo-compresion-OK-1.jpg 800w\" sizes=\"(max-width: 770px) 100vw, 770px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c5ccc22 e-con-full e-flex e-con e-parent\" data-id=\"c5ccc22\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-9117a68 e-con-full e-flex e-con e-child\" data-id=\"9117a68\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c5485e9 elementor-widget elementor-widget-image\" data-id=\"c5485e9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"763\" height=\"1024\" src=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-22_Copia-de-caja-intersomatica-compresion1-Mejorado-SR-OK-1-763x1024.jpg\" class=\"attachment-large size-large wp-image-4696\" alt=\"Spinal Implant Trial\" srcset=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-22_Copia-de-caja-intersomatica-compresion1-Mejorado-SR-OK-1-763x1024.jpg 763w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-22_Copia-de-caja-intersomatica-compresion1-Mejorado-SR-OK-1-223x300.jpg 223w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-22_Copia-de-caja-intersomatica-compresion1-Mejorado-SR-OK-1-768x1031.jpg 768w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-22_Copia-de-caja-intersomatica-compresion1-Mejorado-SR-OK-1.jpg 800w\" sizes=\"(max-width: 763px) 100vw, 763px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1439aef e-con-full e-flex e-con e-child\" data-id=\"1439aef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-62da1ab elementor-widget elementor-widget-heading\" data-id=\"62da1ab\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\nINTERBODY CAGE TESTING\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb826a0 elementor-widget elementor-widget-text-editor\" data-id=\"cb826a0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-985aac3 elementor-widget elementor-widget-text-editor\" data-id=\"985aac3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-2ec8b47 elementor-widget elementor-widget-text-editor\" data-id=\"2ec8b47\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-66114e00 elementor-widget elementor-widget-text-editor\" data-id=\"66114e00\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-985aac3 elementor-widget elementor-widget-text-editor\" data-id=\"985aac3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-20155476 elementor-widget elementor-widget-text-editor\" data-id=\"20155476\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-f7cedb7 elementor-widget elementor-widget-text-editor\" data-id=\"f7cedb7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><p><strong>Interbody cages<\/strong> are devices implanted between vertebral bodies to restore disc height and promote bone fusion in spinal arthrodesis surgeries. At IBV, we perform tests to assess <strong>their mechanical strength, stability, and biological compatibility.<\/strong> <\/p><ul><li><strong>Static and fatigue testing of interbody cages (ASTM F2077)<\/strong>: Simulation of forces applied to the cage across different spinal levels.<\/li><li><strong>Wear and long-term stability assessment (ASTM F2346)<\/strong>: Analysis of material degradation under prolonged usage conditions.<\/li><li><strong>Axial compression and bending tests<\/strong>: Determination of implant resistance under multidirectional loads.<\/li><\/ul><p>These studies ensure that interbody cages meet the mechanical requirements for safe integration into the spine.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7269f7a e-con-full e-flex e-con e-parent\" data-id=\"7269f7a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-a635e55 e-con-full e-flex e-con e-child\" data-id=\"a635e55\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6924484 elementor-widget elementor-widget-heading\" data-id=\"6924484\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">TRANSPEDICULAR FIXATION SYSTEM TESTING\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ac75eb elementor-widget elementor-widget-text-editor\" data-id=\"6ac75eb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-985aac3 elementor-widget elementor-widget-text-editor\" data-id=\"985aac3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-2ec8b47 elementor-widget elementor-widget-text-editor\" data-id=\"2ec8b47\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-66114e00 elementor-widget elementor-widget-text-editor\" data-id=\"66114e00\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-985aac3 elementor-widget elementor-widget-text-editor\" data-id=\"985aac3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-20155476 elementor-widget elementor-widget-text-editor\" data-id=\"20155476\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-f7cedb7 elementor-widget elementor-widget-text-editor\" data-id=\"f7cedb7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-6796ec0a elementor-widget elementor-widget-text-editor\" data-id=\"6796ec0a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-f7cedb7 elementor-widget elementor-widget-text-editor\" data-id=\"f7cedb7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><p><strong>Transpedicular fixation systems<\/strong> consist of pedicle screws and rods used in spinal fusion surgeries to provide segmental stability. At IBV, we evaluate their structural strength and fixation capacity through specific test protocols. <\/p><ul><li><strong>Pullout strength testing of pedicle screws (ASTM F543)<\/strong>: Evaluation of screw anchoring capacity in different bone types.<\/li><li><strong>Fatigue testing of transpedicular fixation systems (ASTM F1717)<\/strong>: Durability analysis of components under repeated loading.<\/li><li><strong>Torsion and stability testing of screws<\/strong>: Measurement of screw resistance to torsional and shear forces.<\/li><\/ul><p>These tests ensure the reliability of spinal fixation systems in vertebral stabilization procedures.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2a90117 e-con-full e-flex e-con e-child\" data-id=\"2a90117\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9fe4a91 elementor-widget elementor-widget-image\" data-id=\"9fe4a91\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"598\" src=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-23_tornillos-pull-out-OK-1.jpg\" class=\"attachment-large size-large wp-image-4698\" alt=\"Spinal Implant Laboratory\" srcset=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-23_tornillos-pull-out-OK-1.jpg 800w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-23_tornillos-pull-out-OK-1-300x224.jpg 300w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-23_tornillos-pull-out-OK-1-768x574.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f74f56 e-con-full e-flex e-con e-parent\" data-id=\"9f74f56\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-63ace7b e-con-full e-flex e-con e-child\" data-id=\"63ace7b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cc06ae7 elementor-widget elementor-widget-image\" data-id=\"cc06ae7\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-24_implantes-columna-fijador-cervical-flexo-compresion-OK-1-768x1024.jpg\" class=\"attachment-large size-large wp-image-4699\" alt=\"Spinal Implant Laboratory\" srcset=\"https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-24_implantes-columna-fijador-cervical-flexo-compresion-OK-1-768x1024.jpg 768w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-24_implantes-columna-fijador-cervical-flexo-compresion-OK-1-225x300.jpg 225w, https:\/\/med-lab.ibv.org\/wp-content\/uploads\/2025\/07\/IMAGEN-24_implantes-columna-fijador-cervical-flexo-compresion-OK-1.jpg 800w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d673992 e-con-full e-flex e-con e-child\" data-id=\"d673992\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e2f4eb0 elementor-widget elementor-widget-heading\" data-id=\"e2f4eb0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">CERVICAL AND THORACIC IMPLANT TESTING\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5211f9 elementor-widget elementor-widget-text-editor\" data-id=\"c5211f9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-985aac3 elementor-widget elementor-widget-text-editor\" data-id=\"985aac3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-2ec8b47 elementor-widget elementor-widget-text-editor\" data-id=\"2ec8b47\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-66114e00 elementor-widget elementor-widget-text-editor\" data-id=\"66114e00\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-985aac3 elementor-widget elementor-widget-text-editor\" data-id=\"985aac3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-20155476 elementor-widget elementor-widget-text-editor\" data-id=\"20155476\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-f7cedb7 elementor-widget elementor-widget-text-editor\" data-id=\"f7cedb7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-6796ec0a elementor-widget elementor-widget-text-editor\" data-id=\"6796ec0a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-f7cedb7 elementor-widget elementor-widget-text-editor\" data-id=\"f7cedb7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><p><strong>Cervical and thoracic implants<\/strong> are subject to different biomechanical demands than lumbar implants due to the increased mobility of these regions. At IBV, we conduct tests specifically adapted to these requirements. <\/p><ul><li><strong>Strength testing of occipito-cervical and thoracic fixation systems (ASTM F2706)<\/strong>: Evaluation of structural stability at the junction between the skull, cervical spine, and thoracic spine.<\/li><li><strong>Flexion and torsion testing of cervical implants<\/strong>: Simulation of physiological movements and assessment of resistance to multidirectional loading.<\/li><li><strong>Fatigue testing of thoracic fixation systems<\/strong>: Determination of durability under prolonged mechanical stress in vertebral stabilization devices.<\/li><\/ul><p>These tests contribute to improving the design of cervical and thoracic implants to ensure their safety in fusion and stabilization surgeries.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1091b0c3 e-con-full e-flex e-con e-parent\" data-id=\"1091b0c3\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-3fe550e7 e-con-full e-flex e-con e-child\" data-id=\"3fe550e7\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11e22f79 elementor-widget elementor-widget-heading\" data-id=\"11e22f79\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\nWHY CHOOSE IBV FOR SPINAL IMPLANT TESTING\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-78992795 e-con-full e-flex e-con e-child\" data-id=\"78992795\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-119b0d43 elementor-widget elementor-widget-text-editor\" data-id=\"119b0d43\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Evaluating a spinal implant is not just about meeting standards \u2014 it requires a <\/span><b>comprehensive approach<\/b> <span style=\"font-weight: 400;\">that combines<\/span><b> mechanical, biomechanical, and clinical-environment interaction testing<\/b><span style=\"font-weight: 400;\">.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4c14aa63 e-con-full e-flex e-con e-child\" data-id=\"4c14aa63\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2e7aff5d elementor-widget elementor-widget-text-editor\" data-id=\"2e7aff5d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-39d6536f e-con-full e-flex e-con e-child\" data-id=\"39d6536f\" data-element_type=\"container\"><div class=\"elementor-element elementor-element-4ec6bfbe elementor-widget elementor-widget-text-editor\" data-id=\"4ec6bfbe\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><div class=\"elementor-element elementor-element-760da53 e-con-full e-flex e-con e-child\" data-id=\"760da53\" data-element_type=\"container\"><div class=\"elementor-element elementor-element-9b53fe7 elementor-widget elementor-widget-text-editor\" data-id=\"9b53fe7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><div class=\"elementor-widget-container\"><p>At IBV we offer:<\/p><ul><li style=\"list-style-type: none;\"><ul><li><strong>Mechanical testing laboratory<\/strong>: Load, fatigue, and structural resistance tests for spinal implants.<\/li><li><strong>Human movement laboratory<\/strong>: Biomechanical analysis applied to the stability and functionality of implants under simulated conditions.<\/li><li><strong>Specialized team in biomechanics and orthopedic materials<\/strong>.<\/li><li><strong>Manufacturer-specific methodology<\/strong>: Custom tests designed according to the implant\u2019s design and materials.<\/li><li><strong>Strategic analysis<\/strong>: We offer technical recommendations to optimize the performance of the implant before its commercialization.<\/li><\/ul><\/li><\/ul><\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6a3c4589 e-flex e-con-boxed e-con e-parent\" data-id=\"6a3c4589\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4fdf0245 elementor-widget elementor-widget-heading\" data-id=\"4fdf0245\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Contact our technical team<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cb90c3f elementor-widget elementor-widget-text-editor\" data-id=\"6cb90c3f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Discover how our testing services can help you evaluate the conformity of your spinal implants before certification and market launch.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a874989 elementor-align-center elementor-mobile-align-center elementor-widget elementor-widget-button\" data-id=\"7a874989\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/med-lab.ibv.org\/en\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contact<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-446f7381 e-flex e-con-boxed e-con e-parent\" data-id=\"446f7381\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-52526a0 elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"52526a0\" data-element_type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<a href=\"https:\/\/med-lab.ibv.org\/\" class=\"elementor-icon\" tabindex=\"-1\" aria-label=\"Back to Essays\">\n\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-up\" viewBox=\"0 0 256 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M88 166.059V468c0 6.627 5.373 12 12 12h56c6.627 0 12-5.373 12-12V166.059h46.059c21.382 0 32.09-25.851 16.971-40.971l-86.059-86.059c-9.373-9.373-24.569-9.373-33.941 0l-86.059 86.059c-15.119 15.119-4.411 40.971 16.971 40.971H88z\"><\/path><\/svg>\t\t\t\t<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<a href=\"https:\/\/med-lab.ibv.org\/\" >\n\t\t\t\t\t\t\tBack to Essays\t\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2e9d4453 e-flex e-con-boxed e-con e-parent\" data-id=\"2e9d4453\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-65127c2f elementor-widget elementor-widget-heading\" data-id=\"65127c2f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Frequently asked questions spinal implant testings<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24c3382d elementor-widget elementor-widget-elementskit-faq\" data-id=\"24c3382d\" data-element_type=\"widget\" data-widget_type=\"elementskit-faq.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"ekit-wid-con\" >\n                <div class=\"elementskit-single-faq elementor-repeater-item-229e3eb\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">\u00bfQu\u00e9 son los ensayos de implantes de columna?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                Son pruebas biomec\u00e1nicas y mec\u00e1nicas que permiten evaluar y validar implantes de columna analizando su resistencia estructural, su comportamiento bajo carga y su estabilidad mec\u00e1nica en distintos segmentos vertebrales.             <\/div>\n        <\/div>\n                <div class=\"elementskit-single-faq elementor-repeater-item-6530ab0\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">\u00bfQu\u00e9 tipos de implantes de columna puede evaluar IBV?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                IBV realiza ensayos para sistemas de fusi\u00f3n intervertebral, cajas intersom\u00e1ticas, sistemas de fijaci\u00f3n transpedicular (tornillos pediculares y varillas) e implantes cervicales y tor\u00e1cicos, adaptando las pruebas al tipo de dispositivo y a la zona anat\u00f3mica.             <\/div>\n        <\/div>\n                <div class=\"elementskit-single-faq elementor-repeater-item-b4f543e\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">\u00bfQu\u00e9 normas se utilizan habitualmente en los ensayos de implantes de columna?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                Seg\u00fan el tipo de implante y prueba, se emplean est\u00e1ndares como ISO 12189 (fatiga en sistemas de fusi\u00f3n espinal) y normas ASTM como F2077 (rigidez\/estabilidad en compresi\u00f3n y flexi\u00f3n y ensayos en cajas intersom\u00e1ticas), F2346 (evaluaci\u00f3n de desgaste\/estabilidad a largo plazo), F543 (resistencia a extracci\u00f3n de tornillos), F1717 (fatiga en fijaci\u00f3n transpedicular) y F2706 (fijaciones occipito-cervicales y tor\u00e1cicas).             <\/div>\n        <\/div>\n                <div class=\"elementskit-single-faq elementor-repeater-item-406280c\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">\u00bfPara qu\u00e9 sirven estos ensayos en el desarrollo y certificaci\u00f3n de un implante de columna?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                Sirven para validar nuevas configuraciones de dise\u00f1o, optimizar materiales y mejorar la biomec\u00e1nica antes de la certificaci\u00f3n. Adem\u00e1s de evidenciar conformidad, IBV puede aportar recomendaciones t\u00e9cnicas para mejorar funcionalidad y seguridad del implante.             <\/div>\n        <\/div>\n                <div class=\"elementskit-single-faq elementor-repeater-item-3ef809c\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">\u00bfQu\u00e9 laboratorio europeo tiene la capacidad de realizar ensayos de implantes de columna?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                El Instituto de Biomec\u00e1nica de Valencia (IBV) es un centro de referencia en Europa para la evaluaci\u00f3n y validaci\u00f3n de implantes de columna, con laboratorios e infraestructura para ensayos mec\u00e1nicos y biomec\u00e1nicos, y un enfoque adaptado a cada fabricante.             <\/div>\n        <\/div>\n                                <script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"\u00bfQu\u00e9 son los ensayos de implantes de columna?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Son pruebas biomec\u00e1nicas y mec\u00e1nicas que permiten evaluar y validar implantes de columna analizando su resistencia estructural, su comportamiento bajo carga y su estabilidad mec\u00e1nica en distintos segmentos vertebrales. \"}},{\"@type\":\"Question\",\"name\":\"\u00bfQu\u00e9 tipos de implantes de columna puede evaluar IBV?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"IBV realiza ensayos para sistemas de fusi\u00f3n intervertebral, cajas intersom\u00e1ticas, sistemas de fijaci\u00f3n transpedicular (tornillos pediculares y varillas) e implantes cervicales y tor\u00e1cicos, adaptando las pruebas al tipo de dispositivo y a la zona anat\u00f3mica. \"}},{\"@type\":\"Question\",\"name\":\"\u00bfQu\u00e9 normas se utilizan habitualmente en los ensayos de implantes de columna?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Seg\u00fan el tipo de implante y prueba, se emplean est\u00e1ndares como ISO 12189 (fatiga en sistemas de fusi\u00f3n espinal) y normas ASTM como F2077 (rigidez\/estabilidad en compresi\u00f3n y flexi\u00f3n y ensayos en cajas intersom\u00e1ticas), F2346 (evaluaci\u00f3n de desgaste\/estabilidad a largo plazo), F543 (resistencia a extracci\u00f3n de tornillos), F1717 (fatiga en fijaci\u00f3n transpedicular) y F2706 (fijaciones occipito-cervicales y tor\u00e1cicas). \"}},{\"@type\":\"Question\",\"name\":\"\u00bfPara qu\u00e9 sirven estos ensayos en el desarrollo y certificaci\u00f3n de un implante de columna?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Sirven para validar nuevas configuraciones de dise\u00f1o, optimizar materiales y mejorar la biomec\u00e1nica antes de la certificaci\u00f3n. Adem\u00e1s de evidenciar conformidad, IBV puede aportar recomendaciones t\u00e9cnicas para mejorar funcionalidad y seguridad del implante. \"}},{\"@type\":\"Question\",\"name\":\"\u00bfQu\u00e9 laboratorio europeo tiene la capacidad de realizar ensayos de implantes de columna?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"El Instituto de Biomec\u00e1nica de Valencia (IBV) es un centro de referencia en Europa para la evaluaci\u00f3n y validaci\u00f3n de implantes de columna, con laboratorios e infraestructura para ensayos mec\u00e1nicos y biomec\u00e1nicos, y un enfoque adaptado a cada fabricante. \"}}]}<\/script>\n                \n    <\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>SPINAL IMPLANT TESTING The Instituto de Biomec\u00e1nica (IBV) is a leading center for the evaluation and validation of spinal implants, offering specialized tests to analyze their structural strength, biomechanical behavior, and mechanical stability across different segments of the spine. Spinal implants must withstand extreme static and dynamic loads while ensuring the stability of the operated [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":4699,"parent":4857,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4867","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/pages\/4867","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/comments?post=4867"}],"version-history":[{"count":16,"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/pages\/4867\/revisions"}],"predecessor-version":[{"id":5797,"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/pages\/4867\/revisions\/5797"}],"up":[{"embeddable":true,"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/pages\/4857"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/media\/4699"}],"wp:attachment":[{"href":"https:\/\/med-lab.ibv.org\/en\/wp-json\/wp\/v2\/media?parent=4867"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}